以作者查詢圖書館館藏 、以作者查詢臺灣博碩士 、以作者查詢全國書目 、勘誤回報 、線上人數:34 、訪客IP:3.148.117.34
姓名 陳俊成(Jun-Cheng Chen) 查詢紙本館藏 畢業系所 機械工程學系 論文名稱 油冷卻器熱傳與壓降性能實驗分析
(Experimental method to test heat transfer performance and pressure drop of aviation oil cooler.)相關論文 檔案 [Endnote RIS 格式] [Bibtex 格式] [相關文章] [文章引用] [完整記錄] [館藏目錄] 至系統瀏覽論文 ( 永不開放) 摘要(中) 本文主要以實驗方法對航空用油冷卻器作熱傳與壓降性能測試及分析。工作流體分別在管側為燃料油(JP-10),在殼側為液壓油(MIL-H-5606),來測試油冷卻器,兩側的工作溫度,在燃料油為40 oC、60 oC、80 oC,而液壓油為80 oC、100 oC、120 oC,而兩側的流量,燃料油為0.9~4 l/min,液壓油為0.9~7.2 l/min。紐賽爾數隨雷諾數變化的情形,於文中詳細探討。
經由壓降與流量的關係圖,可以發現燃料油對液壓油兩側之壓降大致和流量之平方成正比,與一般流體在管內流動之特性相同。但熱傳性能較其他現有熱傳增強管佳。摘要(英) Abstract
This thesis used an experimental method to test heat transfer performance and pressure drop of aviation oil cooler. The working fluids were fuel oil (JP-10) included in tube side and hydraulic pressure oil (MIL-H-5606) that contained in shell side. To test heat transfer effect of our cooler, we taken experimental work temperature to 40oC、60oC、80oC in fuel oil and set hydraulic pressure oil work temperature to 80oC、100oC、120oC.We also set fuel oil side flow rate form 0.9~4l/min and hydraulic pressure oil side from 0.9~7.2l/min.We discussed the relation of Nu number to Re number in detail.
Through all plots of pressure drop to flow rates, we investigated both sides pressure drop of fuel oil and hydraulic pressure oil had proportion to square of flow rate, agreed with viscosity fluid, but heat transfer performance was better than present enhanced heat transfer tubes.關鍵字(中) ★ 增強管
★ 油冷卻器
★ 壓降
★ 熱傳關鍵字(英) ★ pressure drop
★ heat transfer
★ enhanced heat transfer tube
★ oil cooler論文目次 目 錄
頁次
摘要----------------------------------------------------------------------------------- i
目錄----------------------------------------------------------------------------------- ii
表目錄------------------------------------------------------------------------------- iv
圖目錄------------------------------------------------------------------------------- v
符號說明-------------------------------------------------------------------------- viii
第一章 前言------------------------------------------------------------------------ 1
1.1研究動機------------------------------------------------------------------------- 1
1.2研究目的------------------------------------------------------------------------- 2
第二章 文獻回顧------------------------------------------------------------------ 5
2.1扭轉帶----------------------------------------------------------------------------5
2.1.1 扭轉帶管內壓降------------------------------------------------------- 6
2.1.2 扭轉帶管內熱傳-------------------------------------------------------9
2.2 斷續突出-----------------------------------------------------------------------11
2.3 金屬螺旋線--------------------------------------------------------------------12
第三章 實驗方法----------------------------------------------------------------- 20
3.1 簡介----------------------------------------------------------------------------- 20
3.2 實驗系統-----------------------------------------------------------------------20
3.3 實驗量測設備---------------------------------------------------------------- 21
3.3.1 溫度測量--------------------------------------------------------------- 22
3.3.2 壓力測量--------------------------------------------------------------- 22
3.3.3 壓差測量------------------------------------------------------------- 23
3.3.4 流量測量------------------------------------------------------------- 24
3.3.5 資料擷取系統------------------------------------------------------- 24
3.4 實驗步驟--------------------------------------------------------------------- 24
3.4.1變化燃料油側熱傳係數及壓降量測------------------------------ 25
3.4.2變化液壓油側熱傳係數及壓降量--------------------------------- 25
3.4.3燃料油側耐壓實驗量測--------------------------------------------- 26
3.4.4液壓油側耐壓實驗量測--------------------------------------------- 26
3.5 數據換算----------------------------------------------------------------------- 27
3.5.1 壓降實驗-------------------------------------------------------------- 27
3.5.2 熱傳實驗-------------------------------------------------------------- 28
3.5.3修正Wilson圖形法---------------------------------------------------29
第四章 實驗結果與討論------------------------------------------------------- 51
4.1壓降實驗結果--------------------------------------------------------------- 51
4.2熱傳實驗結果--------------------------------------------------------------- 51
第五章 結論------------------------------------------------------------------------ 69
參考文獻----------------------------------------------------------------------------70
附錄----------------------------------------------------------------------------------71參考文獻 參考文獻
Agarwal, S. K. and Raja Rao, M., 1996, “Heat Transfer Augment for the Flow of a Viscous Liquid in Circular Tubes Using Twisted Tape Inserts,” International Journal of Heat and Mass Transfer. Vol. 39, No. 17, pp. 3547 - 3557.
Date, A. W., 1973, “Flow in Tubes Containing Twisted Tapes,” Heating and Ventilating Engineering, Vol. 47, p. 240-248.
Date, A. W., 1989, “Heat Transfer and Pressure Drop Characteristics of Laminar Flow in a Circular Tube Fitted with Regularly Spaced Twisted-Tape Elements,” Experimental Thermal and Fluid Science, No. 2, pp. 310 - 322.
Drizhyus, M. R. M., Shkema, R. K., and Shlanchyauskas A. A., 1980, “Heat Transfer in a Twisted Strean of Water in a Tube,” International Chemical Engineering, Vol. 20, p. 486-497.
Hong, S. W. and Bergles, A. E., 1976, “Augmentation of Laminar Flow Heat Transfer in Tubes by Means of Twisted-Tape Inserts,“ Journal of Heat Transfer, Vol. 98, p. 251-256.
Joshi, S. D. and Bergles, A. E., 1980, “Survey and Evaluation of Passive Heat Transfer Augmentation Techniques for Laminar Flow,” Journal of Thermal Engineering, Vol. 1 No. 3.
Park, Y., Cha, J. and Kim, M, 2002, “Heat Transfer Augmentation Characteristics of Various Inserts in a Heat Exchanger Tube, Journal Enhanced Heat Transfer, Vol. 7, pp. 23 - 33.
Saha, S. K., Dutta, A. and Dhal, S. K., 2001, “Friction and Heat Transfer Characteristics of Laminar Swirl Flow Though a Circular Tube Fitted with Regularly Spaced Twisted-tape Elements,” International Journal of Heat and Mass Transfer, Vol. 44, pp. 4211 - 4223.
Shah, R. K. and London, A. L., 1978, “Laminar flow forced convection in ducts. In Advances in Heat Transfer,” edited by Irvine Jr., T. F. and Hartnett, J. P., Vol. 1 supplement, pp. 379 - 381.
Uttarwar, S. B., 1985, “Augementaion of Laminar Flow Heat Transfer in Tubes by Means of Wire Coil Inserts,” Journal of Heat Transfer, Vol. 107, pp. 930-935.
Wadekar, V., 1998, “Improving Industrial Heat Transfer-compact and Not-so-compact Heat Exchangers,” Journal of Enhanced Heat Transfer, Vol. 5, pp. 53 - 69.
Webb, R. L. 1994, Principles of Enhanced Heat Transfer, pp. 166 - 195.
Xie, L., Gu R. and Zhang, X, 1992, “A Study of the Optimum Inserts for Enhancing Convective Heat Transfer of High Viscosity Fluid in a Tube, in Multiphase Flow and Heat Transfer, Second international Symposium, Vol. 1, pp. 649 - 656.
Xie, L., Gu, R.,and Wang, X, 1988, “Augmentation of Heat Transfer for Single-phase Thermopositive-oil SD280 in the Tube with Inserts,” pp. 113 - 119, in Heat Transfer Enhancement and Energy Conversion edited by Deng, S, Veziroglu, T. N., Tan, Y., and Chen, L., Hemisphere Publishing.
Xie, L., Gu R. and Zhang, X., 1992b, “Friction and Heat Transfer Characteristics in a Tube with a Loose Fitting Twisted-tape Insert,” in Multiphase Flow and Heat Transfer: Second International Symposium, Vo1. 1, edited by Chen. X-J., Veziroglu, T. N., and Tien, C. L., Hemisphere Publishing Corp, New York, pp. 657-661.
顧維藻, 神家銳, 馬重芳, 張玉明,1990,強化傳熱,科學出版社,北京。
王啟川,2001,熱交換器設計,五南出版社,台北。指導教授 楊建裕(Chien-Yuh Yang) 審核日期 2003-7-19 推文 facebook plurk twitter funp google live udn HD myshare reddit netvibes friend youpush delicious baidu 網路書籤 Google bookmarks del.icio.us hemidemi myshare