摘要(英) |
The lateral earth pressure distributions assumed in the current handbooks or guidelines for designing Mechanically Stabilized Earth Wall for evaluating internal stability are not exactly the same. In order to figure out the actual lateral earth pressure distribution acting on a wall, flexible wrapped-face geosynthetic reinforced earth model walls, backfilled with Fulong sand, were constructed and sixteen centrifuge modeling tests were preformed. At the end of reinforcement, the vertical soil pressure is smaller than the theoretical value, while for the lateral soil pressure, except near the toe of wall, is also smaller than the theoretical value. There is no significant difference for the total lateral force; however, larger difference is observed for the moment; the computed values are always smaller than those computed using code specification, indicating that the method adopted in the design guidelines or handbooks is conservative. Within the reinforced zone, the lateral earth pressure, which does not vary significantly with the distance from the wall face, is smaller than the theoretical value from the surface to mid-height of the wall, while the opposite trend is observed for the region below the mid-height of wall. Behind the region of 40mm from the wall face, the vertical soil pressure, which does not vary significantly with the height of wall, decrease with increasing distance from the wall and approach a constant value. |
參考文獻 |
Acutronic, Civil Engineering Centrifuge Model 665-1 Installation Manual 5941E, France, 1992.
Acutronic, Geotechnical Centrifuge Model 665-1 Product Description 5933H, France , 1993.
Acutronic, Geotechnical Centrifuge Model 665-1 Technical Proposal 6022, France, 1993.
Bolton. M.D., Pang, P. L. R., ‘‘Collapse limit states of reinforced earth retaining walls, ’’ Geotechnique, Vol. 32, No.4, pp.349~367, 1982.
Fishman, K. L., C. S. Desai, and R. L. Sogge., ‘‘Field behavior of instrumented geogrid soil reinforced wall, ’’ Journal of Geotechnical Engineering, ASCE, Vol. 119, No.8, pp.1293~1307, 1993.
Jewell, R. A., Millilgan, G. W. E., Sarsby, R. W., and Dubois, D.,“Interaction Between Soil and Geogrids,” Proc. Symp. On PolymerGrid Reinforcement in Civil Engineering, Science and Engineering Research Council and Netlon Limited, March 22~23, 1984.
Mechanically Stabilized Earth Walls and Reinforced Soil SlopesDesign and Construction Guidelines, U.S., Department ofTransportation Federal Highway Administration(FHWA), NHI Course,No. 132042, 2001.
Shahar, Y., S., Frydman, ‘‘Centrifuge modeling of narrow reinforced retaining walls, ’’ Physical Modelling in Geotechnics, pp.1005~1010, 1993.
Yang, Z., “Strength and Deformation characteristics of ReinforcedSand, ” Ph.D Dissertation, University of California at KosAngeles, 1972.
Yoo, N.J., and Ko, H-Y., ”Centrifuge modeling of reinforced earth retaining walls, ”Proceedings, Centrifuge 91, Ko(ed), Balkema, Rotterdam, pp.325~332, 1991.
李咸亨,「神戶地震中加勁擋土牆的行為」,現代營建,第210期,第24~29頁,1997。
李崇正,「離心模型試驗在大地工程之應用」,地工技術雜誌,第36 期,第76~91頁,1991。
周南山,「加勁擋土結構之分析設計及其在公路與高鐵之應用(一)」,現代營建,第216期,第11~18頁,1997。
周南山等人,加勁擋土結構設計及施工手冊,台北市土木技師公會,2001。
周毅等人,土壤力學與基礎工程,台北,2000。
范嘉程、周南山,「加勁擋土結構設計及施工規範“準則”之探討」,地工技術,第70期,第93~106頁,1998。
陳泓文,「砂土坡地井樁受側向力之離心機模型試驗」,博士論
文,國立中央大學土木工程學系,中壢,1999。
陳景文、吳宗欣、Claybourn, A. F.,「不同地工織物擋土牆設計方法之比較」,地工技術雜誌,第43 期,第43~49頁,1993。
陳榮河,「加勁擋土牆之分析與設計」,地工技術,第25期,第46~61頁,1989。
黃景川,「921 集集地震中擋土結構之損害調查與分析」,國家地震工程研究中心研究報告,No. NSC89-2921-Z-319-005-05,台北,2000。 |