English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 78818/78818 (100%)
造訪人次 : 34724534      線上人數 : 951
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/10218


    題名: 使用低壓量測方法之連續血壓量測系統;Continuous Blood Pressure Measurement System Based on Low Cuff Pressure Approach
    作者: 丁蒼毅;Cang-Yi Ding
    貢獻者: 電機工程研究所
    關鍵詞: 低壓量測;血壓;連續;continuous;low cuff pressure approach;blood pressure
    日期: 2007-06-22
    上傳時間: 2009-09-22 12:09:15 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 本論文以長時間連續血壓量測為目的,發展出藉由低度壓力的量測方式加壓於手腕上,以偵測脈搏振幅訊號,進而將此訊號導入本研究當中推導出具有血壓動態追蹤功能之低壓轉換公式,實現低壓連續量測系統。 本系統的量測介面由LabVIEW 7.0規劃完成,並搭配National Instruments USB-6009資料擷取卡,做數位輸出以及類比輸入的工作。壓力感測器的輸出信號包括壓脈袋洩壓過程的信號,以及脈搏振盪的信號,這兩種信號必須透過濾波以及放大電路的設計與之分離,分別傳送到兩個類比輸入通道,以進行血壓參數的計算。 經過實際測試的數據分析,本系統證實了使用低度壓力方式,量測連續血壓的可行性,並且實現了具有血壓動態追蹤功能之低壓連續量測系統。未來可以本系統為基礎,加以改進發展出可攜式二十四小時連續血壓監測儀,以提供更多血壓資訊給學術研究以及臨床醫學上使用。 The main propose of the thesis is to acquire the continuous pulse vibration at the patient’s radial artery based on low cuff pressure approach. By introducing the pulse vibration to the low pressure translating formula of dynamic blood pressure tracking capability, continuous blood pressure measurement system based on low cuff pressure approach is achieved. The interface of the system is completed by LabVIEW 7.0. The digital output and the analog input signals are operated by utilizing National Instruments Data Acquisition (USB-6009) Multifunction I/O Card. There are two kinds of signals at the output of the pressure sensor. They are the signal of cuff pressure and the signal of pulse vibration. A filtering and amplifying circuit is introduced to separate the two signals into two analog input channels of USB-6009. Hence, blood pressure can be calculated after acquiring the data. According to the experimental results, it proves the feasibility of measuring continuous blood pressure by low pressure approach. Moreover, a continuous blood pressure measurement system based on low cuff pressure approach of dynamic blood pressure tacking capability is achieved. 24-hours portable continuous blood pressure measurement instrument could be developed to provide more information for research and medical uses in the future.
    顯示於類別:[電機工程研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明