    题名: 被動冷卻策略:用來降低巴拿馬市的未來住宅計畫耗能的方法;Passive cooling strategies as a method to reduce energy consumption of future dwelling projects in Panama City
    作者: 羅莉涵;Denis,Maria Alejandra Del Rio
    贡献者: 國際永續發展碩士在職專班
    关键词: 被動式冷卻;熱舒適度;自然通風;熱帶氣候;節能;Passive cooling;Thermal comfort;Natural ventilation;Tropical climate;Energy saving
    日期: 2014-06-30
    上传时间: 2014-08-11 18:31:33 (UTC+8)
    出版者: 國立中央大學
    摘要: 本論文的目的是提出一個有效的方法,以降低位於熱帶氣候的巴拿馬市住宅中與熱舒適度相關能源消耗。本文有兩階段架構。首先,進行為期六個月的個案研究:在巴拿馬市一處現有的住宅內放置溫濕度記錄器,以記錄室內的變化。接下來,應用被動式冷卻策略來改善熱表現的概念設計一個住宅原型。本文採用Ecotect軟體進一步模擬出此原型:採用四種不同的自然通風技術來散熱,分別為不通風、全日通風、白天通風、夜晚通風。不論是現有的住宅或是本文提出的原型,都採用自然通風建築的兩套ASHRAE-55熱舒適度標準來評估,即是適應性舒適標準(ACS)與熱舒適度評估指標(PMV)作為熱舒適度量尺。研究結果顯示在此四種自然通風策略中,全日通風表現最佳,能達到最佳熱舒適度。本文主要的兩項發現分別為: (1)為達到最佳被動式冷卻,有必要結合增熱控制與熱散失兩項技術;(2)在未來的巴拿馬市住宅實行被動式冷卻策略,能降低能源消耗並達到熱舒適度。;
    This thesis aimed to propose an effective method to reduce energy consumption related to thermal comfort in residences located in the tropical climate of Panama City. A two-stage framework was adopted in this research. First, a case study was conducted during 6 months; where a humidity-temperature data logger was placed inside an existing house in Panama City to record its indoor conditions. Then, a prototype of house was designed with passive cooling strategies for improving thermal performance. This proposed prototype was further simulated using Ecotect software, where four different natural ventilation techniques for heat dissipation were adopted; namely, no ventilation, full ventilation, day ventilation and night ventilation. Both the existent house and the proposed prototype were evaluated using two ASHRAE-55 thermal comfort standards for naturally ventilated buildings, namely, adaptive comfort standard (ACS) and a predicted mean vote (PMV) regression to use thermal sensation scale. Results shown that among all of the natural ventilation strategies implemented, full ventilation showed the best performances as it was the one to achieve the best thermal comfort. The two major findings of the study are: (1) to fully achieve passive cooling it is necessary to combine heat gain control and heat dissipation techniques, and (2) the implementation of passive cooling strategies can reduce the energy consumption and achieve thermal comfort in future dwellings in Panama City.