中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/68899
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78728/78728 (100%)
造访人次 : 33561994      在线人数 : 681
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/68899


    题名: 開發可攜式阻抗量測儀及其應用
    作者: 賴信宇;Lai,Shin-yu
    贡献者: 電機工程學系
    关键词: 阻抗量測儀;電化學;肌酐酸;人類血清白蛋白;potentiostat;electrochemistry;creatinine;HSA
    日期: 2015-08-05
    上传时间: 2015-09-23 14:46:12 (UTC+8)
    出版者: 國立中央大學
    摘要: 本文提出一個可攜式電化學阻抗量測儀並介紹其應用,可攜式阻抗量測儀具有體積小、成本較低、方便攜帶、量測時間短及即時監控的優點,容易成為床邊檢測儀器,因此,可攜式阻抗量測儀在近幾年迅速成為電化學領域應用於量測的儀器對象。
    本文可攜式阻抗量測儀以ATxmega32A4微處理器為核心,搭配運算放大器TLC2264ID的使用以及電子零件的配置完成硬體的設計;程式碼部分以C語言進行撰寫,燒錄則由AVR studio及燒錄器AVRISP mkII完成。本文可攜式阻抗量測儀重量大約120公克,具有四種量測模式:方波伏安法(SWV)、循環伏安法(CV)、計時電流法(CA)、線性掃描伏安法(LSV);量測範圍為:電壓±990 mV、電流0-50 μA;且在電路校正實驗中獲得和理論值及IM6ex數據值非常接近的實驗數據(誤差< ±2%)。
    在應用方面,藉由多孔網印碳電極的表面改質來量測肌酐酸(Creatinine)與人類血清白蛋白(Human serum albumin, HSA),肌酐酸和微蛋白尿是慢性腎臟病兩個很重要的患病指標,在慢性腎臟病患體內不同濃度的肌酐酸和微蛋白尿可能由不同病程所導致。我們採用三種酵素Creatininase (EC 3.5.2.10)、Creatinase (EC 3.5.3.3)、Sarcosine Oxidase (EC 1.5.3.1)來製成電流式肌酐酸生物感測器,藉由酵素催化肌酐酸使之產生氧化還原反應而可以量到電化學訊號,藉由標準樣品的實驗我們可以了解其電流響應與濃度之間的關係,進而建立檢量線,在0-550 μM的量測區間下獲得高度相關的相關係數(R2=0.997),而在電流式肌酐酸生物感測器的特異性測試中,藉由三種可能出現在人體血液中的干擾物(抗壞血酸、對乙醯胺基酚、尿酸)的測試,對於干擾物所產生的干擾電流我們可以將其平均誤差藉由CA的方法降低到4%以下;而在微蛋白尿的實驗中,將人類血清白蛋白抗體(anti-HSA)固定在電極上形成抗體式多孔網印碳電極,藉由抗體與抗原之間的特異性吸附來捕捉微蛋白尿,純溶液系統在10-300 mg/L量測區間下同樣獲得高度相關的相關係數(R2=0.997),同樣地在特異性測試中也通過在人體尿液中可能出現的四種干擾物(抗壞血酸、葡萄糖、肌酐酸、尿酸)的測試,干擾物所產生的干擾電流其平均誤差藉由CA降低到4%以下。我們也進一步將抗體式多孔網印碳電極和電流式肌酐酸生物感測器應用在實際尿液及血液樣品中,在尿液樣品的檢測實驗中獲得了高度相關的相關係數(R2=0.951)且其線性結果和在標準樣品中所得到的結果也一致,在血液樣品的檢測實驗也獲得高度相關係數(R2=0.979),證明可攜式阻抗量測儀和生物感測器的搭配未來可以應用在實際樣品測量中。
    ;This thesis introduces our development of a portable electrochemical measurement device and its applications. In recent years, the portable potentiostat has become a popular device used in electrochemical measurement. Conventional electrochemical workstations such as IM6ex (ZAHNER-elektrik GmbH & Co. KG, Germany) are expensive, bulky, and need professional operators. On the contrary, our device is portable, inexpensive, and easy to use. The core of the portable impedance measurement device is a 16-bit microprocessor ATxmega32A4 from Atmel. The microprocessor facilitates signal amplification and potential controlling by incorporating the operational amplifier TLC2264ID. The function of the microprocessor is programmed in C language in the integrated development environment provided by Atmel AVR Studio. Weighting 120 g, the portable impedance measurement device provides four measurement modes: square wave voltammetry (SWV), cyclic voltammetry (CV), Chronoamperometry (CA), and linear sweep voltammetry (LSV). The measurement range of the portable device is ±990 mV and 050 μA. Its accuracy was evaluated by comparing its measurement results with those measured with IM6ex as well as the theoretical values. The experiment results showed that the difference is within 2%. We further utilized our portable measurement device to detect creatinine and human serum albumin (HSA) with the screen-printed porous carbon electrode (SPPCE). Creatinine and HSA are important diagnostic indicators of chronic kidney disease (CKD). Different concentrations of creatinine and HSA in patients who suffer from CKD may refer to different levels of CKD. To catalyze creatinine into a redox reaction, we immobilized creatininase (EC 3.5.2.10), creatinase (EC 3.5.3.3), and sarcosine oxidase (EC 1.5.3.1) on the SPPCE to detect the electrochemical signal of creatinine. The creatinine detection results showed a high correlation coefficient (R2 = 0.99) in the calibration line. As for HSA detection, we immobilized anti-HSA on SPPCE to capture HSA by means of the specific adsorption between antibody and antigen. The HSA detection result also showed a high correlation coefficient (R2 = 0.997).
    显示于类别:[電機工程研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML394检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明