    题名: 改善運動中手腕型PPG心率測量;Improvement of Wrist-worn Photoplethysmographic Heart Rate Monitoring during Physical Activities
    作者: 胡君陽;Hu, Jiun-Yang
    贡献者: 電機工程學系
    关键词: 光體積描記法;心率監測;穿戴裝置;動作偽影;Photoplethysmography;Heart Rate Monitoring;Wearable Device;Motion Artifact
    日期: 2017-07-25
    上传时间: 2017-10-27 16:10:21 (UTC+8)
    出版者: 國立中央大學
    摘要: 基於光體積描記法(Photoplethysmography, PPG)的手腕心率監測,使用者在靜態中測量會有較高的準確性,但是在動態中測量則會有較大的誤差。由於PPG訊號會受到手腕動作所引起的偽影雜訊干擾,影響心率測量的準確度。為了改善這個在動態中測量心率的問題,本研究提出一個方法由,來達到抑制動作偽影以及提高心率估計準確度的目的。這方法由兩階段的策略組成。第一階段分析由PPG訊號與三軸加速度訊號所得出的頻譜,利用所提出的抑制動作偽影方法識別出PPG頻譜上的偽影區間並抑制其偽影干擾。第二階段基於短時間內心率的連續性,利用前一刻的心率縮小心率估計的搜尋範圍,提高動態中PPG心率估計的準確性。12位受測者的心率估計誤差平均值為2.57 BPM,有效減少運動過程中所引起的心率測量上的失真。;While the accuracy of heart rate monitoring using photoplethysmography (PPG) is quite acceptable when the person stays still, it could deteriorate during physical activities. The motion artifacts due to hand movements in the received PPG signal interfere with the heart rate detection. In this study, we propose a two-stage strategy to reject the motion artifacts and improve the accuracy of heart rate detection. At the first stage, the frequency spectrum of the received PPG signal is analyzed and the spectral components owing to the motion artifacts are identified and deleted by spectral subtraction. To detect the frequency spectrum of the motion signal, three-axis accelerometers are used. At the second stage, the heart rate is estimated on the basis of the spectral peaks of next moment and the tracking information of previous heart rates. This tracking estimation method has considerably improved the accuracy of PPG heart rate monitoring during physical activities. Experiments with 12 test subjects resulted in an average heart rate error of 2.57 BPM.
    显示于类别:[電機工程研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML215检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明