中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/74912
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41759167      線上人數 : 2016
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/74912


    題名: 應用於遠距醫療照護之無損心電圖壓縮演算法與其嵌入式平台之實現;Implementation of An Effective ECG Lossless Compression Algorithm on the Embedded Platform Combined with the Telemedicine Application
    作者: 郭威廷;Kuo, Wei-Ting
    貢獻者: 電機工程學系
    關鍵詞: 生醫訊號;資料壓縮;Bioengineering Signals;Data Compression
    日期: 2017-07-26
    上傳時間: 2017-10-27 16:11:47 (UTC+8)
    出版者: 國立中央大學
    摘要: 在有著24小時的ECG (Electro-cardiography)心電訊號監護儀器或多導程的心電圖量測裝置如Holter system 能供醫生對患者進行數日之連續心電圖量測的情況下,一個能達到即時且高壓縮率的訊號壓縮處理方法可以有效降低避免心電圖資訊因為長期監測而產生的龐大資料量造成網路頻寬與儲存空間的負擔。然而訊號壓縮可分為無損(Lossless)與有(Lossy)壓縮。對於醫療人員而言,如果能提供即時(Real Time)的無損心電訊號壓縮不但能有效提升醫療人員診斷心血管疾病的準確度也能提供後續的醫療應用。為了達成此目的我們利用參考前幾筆的心電資料之可變動式的預測模組(Adaptive Linear Prediction)來降低動態預測誤差跟一個內容可變式的哥倫布編碼(Content - Adaptive Golomb rice coding)來提升整體系統壓縮率。最後我們也利用 MIT-BIH Arrhythmia 的資料庫包含48組兩導程(Lead II、Lead V1)的心電資料來做壓縮效能評估,結果顯示利用本論文所提出的有效無損心電圖壓縮演算法在經MIT-BIH Lead II資料庫內壓縮率能達到2.77x、經MIT-BIH Lead V1資料庫內壓縮率能達到2.83x。除此之外,我們也將此壓縮演算法開發在嵌入式系統當中能達到方便攜帶並用於遠距醫療之相關應用。
    ;With a 24-hour ECG (Electro-cardiography) signal monitoring system such as Holter system, it would be produced huge amount of data. It is helpful to reduce the data of ECG signal and save storage space by presenting an idea that combine an effective electrocardiogram (ECG) compression algorithm However, signal compression can be divided into lossless and lossy compression. In this thesis, we present an idea that combine an effective ECG lossless data compression with the telemedicine in order to save storage space and reduce transmission time. Different from literatures, we use the Adaptive Linear Prediction to reduce dynamic prediction range and Content – Adaptive Golomb rice coding to raise the compression ratio. Finally, we also take MIT-BIH Arrhythmia Database as the input pattern which contains 48 two-lead recordings, the result show in MIT-BIH Lead II database that compression ratio (CR) is 2.77x and in MIT-BIH Lead V1 database the compression ratio is 2.83x. Furthermore, we also implement the proposed compression algorithm on the embedded development board which is suitable for Telemedicine application.
    顯示於類別:[電機工程研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML237檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明