    題名: Tubular waveguide evanescent field absorption biosensor based on particle plasmon resonance for multiplex label-free detection
    作者: 黃貞翰;Lin, Hsing-Ying;Huang, Chen-Han;Chen, Shin-Huei;Liu, Yu-Chia;Chang, Wei-Zhe;Chau, Lai-Kwan
    貢獻者: 生醫理工學院生醫科學與工程學系
    關鍵詞: Absorption;antibodies;Biological and medical sciences;Biological Assay - instrumentation;Biosensing Techniques - instrumentation;Biosensor;Biosensors;Biotechnology;coatings;detection limit;Equipment Design;Equipment Failure Analysis;Fundamental and applied biological sciences. Psychology;High-throughput biochemical detection;Immunoassay - instrumentation;Light;Localized surface plasmon resonance;Methods. Procedures. Technologies;monitoring;Nanoparticle;Optical waveguide;refractive index;Refractometry - instrumentation;Reproducibility of Results;screening;Sensitivity and Specificity;Staining and Labeling;streptavidin;Surface Plasmon Resonance - instrumentation;urine;Various methods and equipments
    日期: 2013-03-15
    上傳時間: 2026-04-23 11:23:12 (UTC+8)
    出版者: Elsevier Ltd.;Kidlington: Elsevier B.V
    摘要: 摘要: A novel tubular waveguide particle plasmon resonance (TW-PPR) sensor is demonstrated for label-free biochemical detection. The sensor itself is a microchamber of a defined sample volume, a mechanical support for sensor coating, a waveguide to provide evanescent wave interrogation, and it can be easily extended to a multi-channel format. The sensor resolution is estimated to be 2.6×10−6RIU in measuring solutions of various refractive indices. The sensing system can perform multiple measurements simultaneously and its limit of detection for anti-DNP antibody and streptavidin is 1.2×10−10g/ml (0.55pM) and 2.3×10−10g/ml (3.5pM), respectively. Accurate determination of these analytes with known concentration spiked in artificial urine were examined and the bias is less than ±7%, supporting the utility of the device for analyte screening in more complex media. The TW-PPR sensor can be inexpensively fabricated and has a special niche for monitoring biomolecular interactions in real-time, hence it is ideally suitable for disposable uses, especially promising for convenient high-throughput biochemical sensing applications. ► A tubular waveguide particle plasmon resonance sensor is used for label-free biochemical sensing. ► It relies on an unsophisticated light intensity interrogation scheme. ► A multi-channel sensing system is developed for higher-throughput biochemical detection.
    其他題名: Biosens Bioelectron
    出版者: Kidlington: Elsevier B.V
    出版日期: 2013-03-15
    出處: Biosensors & bioelectronics, 2013-03, Vol.41, p.268-274
    版權: 2012 Elsevier B.V.
    版權: 2014 INIST-CNRS
    版權: Copyright © 2012 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0956-5663
    識別號: ISSN: 1873-4235
    識別號: EISSN: 1873-4235
    識別號: DOI: 10.1016/j.bios.2012.08.041
    識別號: PMID: 22964381
    顯示於類別:[生醫科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML19檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明