 |
English
|
正體中文
|
简体中文
|
全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81663423
線上人數 : 4048
|
|
|
資料載入中.....
|
請使用永久網址來引用或連結此文件:
https://ir.lib.ncu.edu.tw/handle/987654321/108215
|
| 題名: | A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant |
| 作者: | 潘敏俊;Pan, Min-Chun;Zhuang, Han-Bo;Chen, Chin-Sung;Wu, Jer-Whey;Lee, Shyh-Yuan |
| 貢獻者: | 工學院機械工程學系 |
| 關鍵詞: | Bone and Bones - physiology;Dental implant;Dental Implants;Interfacial bone defect;Materials Testing - methods;Noncontact detection;Osseointegration;Radiology;Resonance frequency analysis |
| 日期: | 2013-12-01 |
| 上傳時間: | 2026-04-23 14:39:20 (UTC+8) |
| 出版者: | Elsevier BV;England: Elsevier Ltd |
| 摘要: | 摘要: This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired with a capacitance sensor. The spectral analysis was used to characterize the first RF value. Two types of in vitro defect models, Buccal-Lingual (BL) and Mesial-Distal (MD), were constructed for the verification. The measurements of the RF for a defect model clamped at four different heights (9, 10, 11, and 12mm) were performed in two sensing directions (BL and MD). Moreover, each model was also analyzed using an Osstell Mentor. The obtained two parameters, RF and ISQ (Implant Stability Quotient), were statistically analyzed through one-way analysis of variance (ANOVA) and linear regression analysis for comparisons. The RF and the ISQ values obtained for all of the defect models at the four clamp heights decreased significantly (p<0.05) with an increase in the severity of the defect. The two parameters for each imperfection increase significantly (p<0.05) with an increase in the clamp height. Additionally, the RFs of all of the defect models are linearly correlated with their corresponding ISQs for the four clamp heights and the two measuring orientations. Therefore, our developed technique is feasible for the assessment of the postoperative healing around a dental implant. 其他題名: Med Eng Phys 出版者: England: Elsevier Ltd 出版日期: 2013-12-01 出處: Medical engineering & physics, 2013-12, Vol.35 (12), p.1825-1830 版權: 2013 IPEM 版權: IPEM 版權: Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved. 識別號: ISSN: 1350-4533 識別號: ISSN: 1873-4030 識別號: EISSN: 1873-4030 識別號: DOI: 10.1016/j.medengphy.2013.05.006 識別號: PMID: 23764430 |
| 顯示於類別: | [機械工程學系] 期刊論文
|
文件中的檔案:
| 檔案 |
描述 |
大小 | 格式 | 瀏覽次數 |
| index.html | | 0Kb | HTML | 24 | 檢視/開啟 |
|
在NCUIR中所有的資料項目都受到原著作權保護.
|
::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::