中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/108461
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82917844      在线人数 : 1895
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108461


    题名: Characterizing aberration of a pressure-actuated tunable biconvex microlens with a simple spherically-corrected design
    作者: 傅尹坤;Fuh, Yiin-Kuen;Lin, Ming-Xin;Lee, Shyong
    贡献者: 工學院機械工程學系
    关键词: Aberration;Biconvex membrane lens;Design engineering;Dynamical systems;Dynamics;Fluid dynamics;Fluid flow;Fluids;Microlens;Spherical aberration;Thickness ratio;Tunable lens;ZEMAX simulation
    日期: 2012-12-01
    上传时间: 2026-04-23 14:50:33 (UTC+8)
    出版者: Elsevier Ltd.;Elsevier Ltd
    摘要: 摘要: A tunable biconvex microlens of 1000μm diameter is micromachined and pressure-actuated for variable-focusing applications. The microlens consists of two thin membranes with reconfigurable shapes: a fluid chamber and the interconnected microchannel. The back focus length tuning range is demonstrated from 35mm to 250mm and zoom ratio of up to seven without any mechanical moving components. Aberration characterization is carried out systematically by the Shack–Hartmann measurements to clarify the potential adverse effect associated with focal length tunability, with particular attention placed on interpretation of the Zernike modes. Experimental results show that spherical mode (Z13) can be significantly degraded from −0.037μm to −0.095μm by injecting DI water of 1.11–4.43μL. A facile and cost-efficient approach has been proposed to compensate spherical aberration based on differential thickness of elastic membranes. The thickness variation for the biconvex microlenses can be manipulated as the difference in deformation contour as well as the resultant surface profile when subjected to uniform applied pressure. Both ZEMAX simulation and experiment are used to validate the design concept and search for the optimal thickness ratio. By injecting the fixed fluid volume of 3.32μL, the optimal thickness ratio of 1:4 can be experimentally obtained and the measured spherical aberration is −0.023μm, or 56% improvement compared with 1:1 thickness ratio of −0.053μm. The proposed microlens is robust and can be used potentially in medical imaging systems, for example, a dynamic environment and adaptive optics. ► A tunable biconvex microlens of 1000μm diameter is micromachined. ► The back focus length tuning range is demonstrated from 35mm to 250mm. ► Zoom ratio of up to seven is achieved without any mechanical moving components. ► A facile design to compensate spherical aberration based on differential thickness. ► Proposed microlens can be used potentially in medical imaging systems.
    出版者: Elsevier Ltd
    出版日期: 2012-12
    出處: Optics and lasers in engineering, 2012-12, Vol.50 (12), p.1677-1682
    資源來源: Elsevier ScienceDirect Journals Complete
    版權: 2012
    識別號: ISSN: 0143-8166
    識別號: EISSN: 1873-0302
    識別號: DOI: 10.1016/j.optlaseng.2012.07.013
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML14检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明