中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/108680
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82911113      在线人数 : 2243
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108680


    题名: Effect of flow direction for the heat transfer performance of refrigerant R-410A evaporation in a plate heat exchanger
    作者: 楊建裕;Yang, Chien-Yuh;Lin, Yueh-Hung;Lin, Fu-Chen
    贡献者: 工學院機械工程學系
    关键词: Applied sciences;Counterflow;Devices using thermal energy;Energy;Energy. Thermal use of fuels;Evaporation;Exact sciences and technology;Flow velocity;Heat exchangers;Heat exchangers (included heat transformers, condensers, cooling towers);Heat transfer;Heat transfer coefficients;Plate heat exchangers;Refrigerants;Refrigerating engineering;Refrigerating engineering. Cryogenics. Food conservation;Saturation;Temperature effects
    日期: 2013-06-28
    上传时间: 2026-04-23 15:01:59 (UTC+8)
    出版者: Taylor and Francis Ltd.;Philadelphia, PA: Taylor & Francis Group
    摘要: 摘要: This article provides an experimental investigation of the effect of flow direction for refrigerant R-410A evaporated in a plate heat exchanger. Parallel-flow and counterflow arrangements with 2°C and 5°C exit superheat conditions were tested. The refrigerant entered the test section at a vapor quality of 0.24 and evaporated at a saturation temperature of 1.1°C. The experimental results were analyzed by the evaporation heat transfer coefficient and overall average heat transfer coefficient separately. The evaporation heat transfer coefficient in parallel-flow arrangement is higher than that in the case of counterflow arrangement. However, the average heat transfer coefficients are affected not only by the flow direction, but also by the exit superheat condition. The interaction of these two effects causes there to be almost no difference of the average heat transfer performance between these two flow arrangements for low exit superheat condition. While the refrigerant exit superheat is high, the overall heat transfer performance of the parallel-flow case is lower than that of the counterflow case.
    出版者: Philadelphia, PA: Taylor & Francis Group
    出版日期: 2013-10-21
    出處: Heat transfer engineering, 2013-10, Vol.34 (13), p.1133-1139
    資源來源: EBSCOhost Academic Search Premier
    版權: Copyright Taylor & Francis Group, LLC 2013
    版權: 2014 INIST-CNRS
    版權: Copyright Taylor & Francis Ltd. 2013
    識別號: ISSN: 0145-7632
    識別號: EISSN: 1521-0537
    識別號: DOI: 10.1080/01457632.2013.763553
    識別號: CODEN: HTEND2
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML16检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明