    題名: Effect of flow direction for the heat transfer performance of refrigerant R-410A evaporation in a plate heat exchanger
    作者: 楊建裕;Yang, Chien-Yuh;Lin, Yueh-Hung;Lin, Fu-Chen
    貢獻者: 工學院機械工程學系
    關鍵詞: Applied sciences;Counterflow;Devices using thermal energy;Energy;Energy. Thermal use of fuels;Evaporation;Exact sciences and technology;Flow velocity;Heat exchangers;Heat exchangers (included heat transformers, condensers, cooling towers);Heat transfer;Heat transfer coefficients;Plate heat exchangers;Refrigerants;Refrigerating engineering;Refrigerating engineering. Cryogenics. Food conservation;Saturation;Temperature effects
    日期: 2013-06-28
    上傳時間: 2026-04-23 15:01:59 (UTC+8)
    出版者: Taylor and Francis Ltd.;Philadelphia, PA: Taylor & Francis Group
    摘要: 摘要: This article provides an experimental investigation of the effect of flow direction for refrigerant R-410A evaporated in a plate heat exchanger. Parallel-flow and counterflow arrangements with 2°C and 5°C exit superheat conditions were tested. The refrigerant entered the test section at a vapor quality of 0.24 and evaporated at a saturation temperature of 1.1°C. The experimental results were analyzed by the evaporation heat transfer coefficient and overall average heat transfer coefficient separately. The evaporation heat transfer coefficient in parallel-flow arrangement is higher than that in the case of counterflow arrangement. However, the average heat transfer coefficients are affected not only by the flow direction, but also by the exit superheat condition. The interaction of these two effects causes there to be almost no difference of the average heat transfer performance between these two flow arrangements for low exit superheat condition. While the refrigerant exit superheat is high, the overall heat transfer performance of the parallel-flow case is lower than that of the counterflow case.
    出版者: Philadelphia, PA: Taylor & Francis Group
    出版日期: 2013-10-21
    出處: Heat transfer engineering, 2013-10, Vol.34 (13), p.1133-1139
    資源來源: EBSCOhost Academic Search Premier
    版權: Copyright Taylor & Francis Group, LLC 2013
    版權: 2014 INIST-CNRS
    版權: Copyright Taylor & Francis Ltd. 2013
    識別號: ISSN: 0145-7632
    識別號: EISSN: 1521-0537
    識別號: DOI: 10.1080/01457632.2013.763553